BPXMQ - DEVFLEX 601 595-A-26493 PEARL GRAY, 601S299

  • MSDS: BPXMQ
  • Manufacturer: DEVOE COATINGS CO
  • Product Name: DEVFLEX 601 595-A-26493 PEARL GRAY, 601S299
  • National Stock Number: 8030-00N034276
Product Identification

Product ID:DEVFLEX 601 595-A-26493 PEARL GRAY, 601S299
MSDS Date:10/02/1990
FSC:8030
NIIN:00N034276
MSDS Number: BPXMQ

Responsible Party
DEVOE COATINGS CO
4000 DUPONT CIRCLE
LOUISVILLE, KY 40207
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 502-897-9861

Cage: 1HK86

Contractor
DEVOE COATINGS CO
7600 LOUISVILLE, KY 40207-4802 US

Telephone: 502-897-9861

Cage: 1HK86

Ingredients

ACRYLIC RESIN

Fraction By Weight: <5%


ANTIMONY OXIDE; (ANTIMONY TRIOXIDE) (SARA III)

CAS: 1309-64-4

RTECS: CC5650000

Fraction By Weight: <5%

OSHA PEL 0.5 MG/M3 (SB)

ACGIH TLV: 0.5 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYLENE, CHLORO-, POLYMER; (POLYVINYL CHLORIDE RESIN)

CAS: 9002-86-2

RTECS: KV0350000

Fraction By Weight: <5%


<0.1

CAS: 34590-94-8

RTECS: JM1575000

Fraction By Weight: <5%


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 15%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


VINYL ACETATE (RESIN)

Fraction By Weight: 25%


17.5

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 40%


130.55 G/L

RTECS: 9999999VO


A COMBINATION OF PARTICULATES AND VPAOR. WHEN

RTECS: 9999999ZZ


SUPPLY RESP OR HOODS.USE NIOSH/MSHA APPRVD RESP WHEN

RTECS: 9999999ZZ


WITH THIS PRODUCT. FOLLOW RESPIRATOR MANUFACTURER'S

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: BREATHING: IRRITATION OF THE
RESPIRATORY TRACT; HEADACHE, NAUSEA, DIZZINESS. SKIN/EYE: PRIMARY
IRRITATION. CHRONIC: PROLONGED AND REPEATED BREATHING OF SPRAY MIST
AND/OR SANDING DUST OVER A PER IOD OF YEARS MAY CAUSE DUST DISEASE
OF THE LUNGS.
Explanation of Carcinogenicity:ANTIMONY TRIOXIDE GROUP 2B (IARC)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. EYES: FLUSH IMMED WITH LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MIN. CONSULT A PYSICIAN FOR
MEDICAL TREATMENT. SKIN: REMOVE WITH SOAP AND WATER. REMOVE SOILED
CLOTHING. INGES T: DRINK 1 TO 2 GLASSES OF WATER TO DILUTE. DO NOT
INDUCE VOMITING. CONSULT PHYSICIAN IMMEDIATELY. TREAT
SYMPTOMATICALLY.

Fire Fighting

Flash Point:NONE
Lower Limits:1.1 %
Extinguishing Media:IN CASE OF FIRE USE CO*2, DRY CHEM, FOAM OR OTHER
NFPA APPROVED METHOD FOR TREATING CLASS B FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFTIVE. IF H*2O IS USED, FOG NOZZ ARE
PREFERABLE. IF EXPOSED TO FIRE OR (SUPP DATA)
Unusual Fire/Explosion Hazard:DUE TO PRESSURE BUILD-UP, CLSD CNTNRS
EXPOSED TO EXTREME HEAT MAY EXPLODE. DURING EMERGENCY CONDITIONS,
OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. (SUPP DATA)

Accidental Release

Spill Release Procedures:WASH WITH WATER. BEFORE ATTEMPTING CLEAN-UP,
REFER TO HAZARD CAUTION INFORMATION IN OTHER SECTIONS OF THIS
MATERIAL SAFETY DATA FORM. CONTAIN SPILLED MATERIAL AND REMOVE WITH
INERT ABSORBENT. STORE IN CLOSED CONTAINER UNTIL PROPERLY DISPOSED
OF.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:DO NOT BRTH VAPS, SPRAY MIST/SANDING DUST. WHEN
SPRAY APPLIED IN OUTDOOR/OPEN AREAS W/UNRESTRICTED VENT, & DURING
SANDING/GRINDING OPERATIONS, USE NIOSH/MSHA APPRVD MECH FILTER RESP
TO REMOVE SOLID AI RBORNE PRACT OF OVERSPRAY & (SUPP DATA)
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:EXTREME HEAT, H*2O SHLD BE USED TO COOL CLOSED CNTNRS &
PVNT PRESS BUILD-UP/POSS AUTO-IGNITION. EXPLO HAZ: SYMPTOMS MAY NOT
BE IMMEDIATELY APPARENT. OBTAIN MEDICAL ATTENTION. RESP PROT :
SANDING DUST. WHEN USED IN RESTRICTEDVENT AREAS, WEAR NIOSH/MSHA
APPRVD CHEM/MECH FILTERS DESIGNED TO REMOVE(ING 9)

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:59.84

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE HAZ FUMES WHEN HEATED TO
DECOMP. FUMES MAY CNTN CO, CO*2, NO*X. CHLORINE/HCL, OXIDES &
CHLORIDES OF ANTIMONY.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCOREDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.